Pull wire sensor installation procedures and maintenance!

Changchun Rongde Optics Co.,Ltd.   Release time:2017-11-29   Browse:974

Pull wire sensor installation procedures and maintenance:

Note: A, the product in the installation process has the following dangers - when the wire rope is pulled out, it is forbidden to let go suddenly, because after the wire rope pulled out to tighten the tension, if suddenly let go, Tension under the action of high-speed fight back, may cause some damage to equipment and personnel.

B, the sensor installation and work can not exceed the maximum travel (from the original rope clamp 2 meters), nor the original rope rope rope release, otherwise it will cause damage to the sensor.

C, this product may not disassemble, if found, is not covered under the warranty. Installation procedure:

1). Fix the sensor to the mounting bracket through the mounting hole.

2). The wire rope at a speed of less than 2 m / min pulled out to the maximum range, in the process of pulling out, to keep the wire rope and the rope does not rub the rope pulled out direction should be parallel with the side of the body, (During this process, it is forbidden to loosen the wire rope and retract the wire rope without restraint, which will seriously damage the sensor.) Adjust the mounting bracket and rope outlet, the minimum stroke measuring point, the maximum stroke measuring point Position each other to ensure that the three points in a line, and the sensor side of the parallel error of less than 1 °; Slowly back the wire rope.

 3) Straighten the wire rope at the minimum stroke of work and keep the wire rope parallel to the side of the sensor.

4) If the rope head is fixed at the maximum stroke of the work, the wire rope should be pulled out to be greater than the maximum stroke, then the wire rope is clamped by the tool at the rope outlet, and then the wire rope rope head is fixed.

5) The wire rope is made of stainless steel and is used outdoors , A little oil on a regular basis, it is recommended to regularly replace the wire rope. Maintenance: This equipment has been waterproof installation design, but in order to ensure long-term use outdoors, it is recommended to increase the rain and waterproof protection. Rope in the course of the operation can not be hooked, hanging object. Regular cleaning of the wire rope and oil Note In any case, To ensure the direction of rope movement and rope out of the vertical. If any deviation, timely adjustment.



Previous:How to choose incremental encoder and absolute encoder?
Next:Wire encoder pull wire encoder displacement sensor

[Return to the previous page]